Warning: fopen(/home/virtual/enm-kes/journal/upload/ip_log/ip_log_2025-02.txt): failed to open stream: Permission denied in /home/virtual/lib/view_data.php on line 100 Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 101 Comparative Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Radioimmunoassay in Determining Plasma Aldosterone Concentration and Plasma Renin Activity for Primary Aldosteronism Screening
Skip Navigation
Skip to contents

Endocrinol Metab : Endocrinology and Metabolism

clarivate
OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Endocrinol Metab > Volume 39(6); 2024 > Article
Brief Report
Adrenal gland Comparative Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Radioimmunoassay in Determining Plasma Aldosterone Concentration and Plasma Renin Activity for Primary Aldosteronism Screening
So Yoon Kwon1orcid, Kyeong-Jin Kim2, Soo-Youn Lee3, Jae Hyeon Kim2orcid
Endocrinology and Metabolism 2024;39(6):965-969.
DOI: https://doi.org/10.3803/EnM.2024.1985
Published online: November 15, 2024

1Division of Endocrinology and Metabolism, Department of Internal Medicine, Daegu Catholic University Hospital, Daegu Catholic University School of Medicine, Daegu, Korea

2Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

3Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

Corresponding author: Jae Hyeon Kim. Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Korea Tel: +82-2-3410-1580, Fax: +82-2-3410-3849, E-mail: jaehyeon@skku.edu
• Received: March 15, 2024   • Revised: June 17, 2024   • Accepted: August 2, 2024

Copyright © 2024 Korean Endocrine Society

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 546 Views
  • 27 Download
prev next
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) accurately measures plasma aldosterone concentration (PAC), but its correlation with radioimmunoassay (RIA), equivalent RIA levels, and optimal cutoff for PAC and aldosterone-to-renin ratio (ARR) in primary aldosteronism (PA) screening have not been determined in a Korean population. Our study of 127 patients who underwent diagnostic testing for PA showed that the LC-MS/MS and RIA methods have good correlation, with a mean bias of 29.3% for PAC. An LC-MS/MS PAC level of 11.7 ng/dL was equivalent to an RIA PAC level of 15 ng/dL. Receiver operating characteristic curve analysis showed that an LC-MS/MS PAC level of 10.3 ng/dL and LC-MS/MS ARR level of 20.0 provided sensitivity of 73.1% with a specificity of 57.3% and sensitivity of 92.3% with a specificity of 14.7%, respectively. When the LC-MS/MS method is used for PA screening, an adjustment of cutoff values is necessary.
Primary aldosteronism (PA) is the foremost endocrine cause of secondary hypertension, which is associated with a higher risk of target organ complications compared to essential hypertension (ET) [1,2]. A retrospective study of Korean patients showed that approximately 30% of hypertensive patients had positive screening results for PA, with 6% eventually confirmed for the disease, which suggests that PA may be more prevalent than generally recognized [3]. In this context, an accurate and sensitive screening test for PA is needed.
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) for measuring plasma aldosterone concentration (PAC) and plasma renin activity (PRA) is highly accurate and reliable in diagnosing PA [4,5]. However, in the Korean population, immunoassay methods are predominantly used for measuring PAC and PRA, and the established cutoff values for PA are based on immunoassay measurements [6]. Moreover, comparative studies between LC-MS/MS and immunoassay methods are scarce in the Korean population.
Our study aimed to evaluate the correlation between LC-MS/MS and radioimmunoassay (RIA), to determine the RIA equivalent value of LC-MS/MS, and to analyze optimal PAC cutoff values using LC-MS/MS for PA screening in a Korean population.
Our study entailed a retrospective analysis of patients who were screened and underwent confirmatory testing for PA at Samsung Medical Center from January 2018 to November 2021. We reviewed 253 patients with hypertension (defined as systolic blood pressure [SBP] ≥140 mm Hg, diastolic blood pressure [DBP] ≥90 mm Hg, or use of antihypertensive medication) who underwent PAC and PRA assessment using both RIA and LC-MS/MS on the same day at an outpatient clinic. Inclusion was based on the presence of at least one of the following: younger than 40 years, grade 3 hypertension (SBP ≥160 mm Hg or DBP ≥100 mm Hg), hypertension with three or more antihypertensive medications, hypokalemia, adrenal mass, atrial fibrillation, a family history of PA in first-degree relatives, or a family history of stroke before the age of 40 [6]. The 82 individuals who did not meet these criteria were excluded. Thirty patients who had taken beta blockers, diuretics, or angiotensin receptor blockers within the prior 2 weeks or mineralocorticoid receptor antagonists in the prior 4 weeks to screening were excluded. We also excluded 14 patients who were suspected of autonomous cortisol secretion, defined as a cortisol level of more than 1.8 μg/dL after a 1 mg dexamethasone suppression test, or pheochromocytoma based on biochemical tests or imaging [7]. Consequently, 127 individuals were entered in the analysis.
We defined patients with PA or ET by the seated saline loading test using an LC-MS/MS PAC cutoff value of 5.8 ng/dL and RIA PAC cutoff value of 6.0 ng/dL [6,8]. Detailed explanations of the LC-MS/MS and RIA analytical methodologies are available in our preceding research paper [9]. Given that diabetes mellitus (DM) can influence PAC [10], we identified 31 patients with DM based on the prescription of DM medication, hemoglobin A1c ≥6.5%, or fasting blood glucose ≥126 mg/dL, to account for its potential impact on PAC measurements. An independent t test and the chi-square test were used to compare data between the PA and ET groups, and DM and non-DM groups. Passing-Bablok regression analysis and Bland-Altman analysis assessed the correlation and agreement between PAC and PRA by LC-MS/MS and RIA. The diagnostic performances and optimal cutoff values of PAC and aldosterone-to-renin ratio (ARR) by LC-MS/MS were evaluated using the receiver operating characteristic (ROC) curves analysis. Analyses were performed using MedCalc version 20 (MedCalc Software, Ostend, Belgium). The study protocol was approved by the Institutional Review Board (IRB) of Samsung Medical Center. The need for informed consent was waived (IRB No. 2023-02-053) because the study was retrospective and analyzed de-identified data.
Supplemental Table S1 shows the characteristics and screening test results for PA in both the PA-confirmed group and the ET group. In both groups, the levels of LC-MS/MS PAC and LCMS/MS ARR were lower than those of RIA PAC and RIA ARR. PRA demonstrated no significant differences between the RIA and LC-MS/MS methods, which may be attributed to the general suppression of PRA in this study population, likely due to selection of patients with sufficient suspicion of PA to warrant confirmatory testing. T-tests shows no significant difference in LC-MS/MS PAC and RIA PAC between patients with and without DM (P=0.90 and P=0.76, respectively) (Supplemental Table S2).
According to Passing-Bablok regression analysis, the correlation between LC-MS/MS and RIA methods for PAC and PRA was good, with coefficients of 0.82 (95% confidence interval [CI], 0.76 to 0.87; P<0.001) (Fig. 1A) and 0.84 (95% CI, 0.77 to 0.88; P<0.001) (Fig. 1B), respectively. The regression equation was y=–0.51+0.81χ for PAC and y=0.06+0.78χ for PRA when χ was RIA and y was LC-MS/MS. According to the equation, an RIA PAC value of 15 ng/dL, the conventional threshold value for screening of PA, was equivalent to an LC-MS/MS PAC value of 11.7 ng/dL. Bland-Altman analysis showed that LC-MS/MS and RIA have a mean bias of 29.3% (95% CI, 24.0 to 34.5) (Fig. 1C) for PAC and a mean bias of 13.4% (95% CI, 5.9 to 20.9) (Fig. 1D) for PRA.
ROC curve analyses assessed the ability of LC-MS/MS PAC and LC-MS/MS ARR to discriminate between ET and PA patients (Supplemental Fig. S1). For the LC-MS/MS PAC and ARR, the area under the curve (AUC) values were 0.74 (95% CI, 0.66 to 0.81; P<0.001) and 0.70 (95% CI, 0.61 to 0.77; P<0.001), respectively. The AUC for RIA PAC was 0.78 (95% CI, 0.68 to 0.88), and for RIA ARR, it was 0.68 (95% CI, 0.58 to 0.78). Comparison between RIA and LC-MS/MS methods for both PAC and ARR yielded P=0.09 and P=0.98, respectively, indicating no significant differences. An LC-MS/MS PAC cutoff level of 10.3 ng/dL yielded a sensitivity of 73.1% and a specificity of 57.3%. An LC-MS/MS ARR cutoff level of 20.0 ng/dL per ng/mL/hr demonstrated a sensitivity of 92.3% and a specificity of 14.7% (Table 1). The discriminative ability of LC-MS/MS PAC and ARR to distinguish between PA and ET patients remains consistent when DM is included as a covariate (LC-MS/MS PAC AUC=0.74 [95% CI, 0.60 to 0.79]; LC-MS/MS ARR AUC=0.71 [95% CI, 0.62 to 0.76]) (Supplementary Fig. S2).
In this study, we evaluated the correlation of LC-MS/MS with RIA and the optimal cutoff values of LC-MS/MS PAC and ARR for screening PA in a Korean population with hypertension. Our results indicate a strong correlation and agreement between LCMS/MS and RIA methods for measuring PAC and PRA. ROC curve analyses further supported the diagnostic utility of LCMS/MS, with optimal cutoff levels for PAC and ARR (10.3 ng/ dL and 20.0 ng/dL per ng/mL/hr, respectively) demonstrating reasonable sensitivity and specificity.
Our data indicated that the average PAC values obtained through LC-MS/MS were lower than those measured by RIA. This finding is consistent with the results of previous studies [9,11,12]. Guo et al. [11] demonstrated that RIA measurements are approximately 59% higher on average compared to LC-MS/MS. Similarly, Thuzar et al. [12] found RIA PAC were 17% to 29% higher than those obtained by LC-MS/MS. In our study, a mean bias of 29.3% was detected, which is within the range reported by these studies [11]. The lower PAC values in LC-MS/MS compared to RIA may stem from the cross-reactivity of the test method with steroids structurally similar to aldosterone [13]. Therefore, PAC values measured by immunoassays may exhibit reduced specificity relative to LC-MS/MS. This finding holds particular significance since our analysis revealed that the conventional RIA PAC threshold for PA screening (15 ng/dL) is equivalent to a lower LC-MS/MS value (11.7 ng/dL), and the optimal cutoff levels for LC-MS/MS PAC and LC-MS/MS ARR were lower than the conventional cutoff levels with immunoassay. This discrepancy underscores the need for revised cutoff values for LC-MS/MS to increase the accuracy of PA screening in clinical settings.
A notable limitation of this study is its single-center design, conducted in a tertiary hospital setting that predominantly included patients referred from primary care clinics. This could limit the generalizability of our findings. Therefore, conducting multi-center studies with varied population is essential for broader validation. While we established cutoff values for LCMS/MS PAC and ARR in the Korean demographic, further research comparing other diagnostic methods is required to evaluate their relative effectiveness. Although the specificity of LCMS/MS ARR in this study is low (14.7%), as noted in a previous meta-analysis, the specificity of ARR may be variable, and a single ARR cutoff cannot be recommended [14]. However, the high sensitivity of LC-MS/MS ARR (92.3%) in this study suggests its usefulness for screening PA patients who require further diagnostic testing. It is our hope that future research and revisions to clinical guidelines will consider these findings to enhance the precision of PA diagnosis when using LC-MS/MS.
In conclusion, adjusting cutoff values for PAC is necessary when the LC-MS/MS method is utilized for screening PA in clinical practice.

Supplemental Table S1.

Characteristics and Screening Results of Primary Aldosteronism in the Primary Aldosteronism and Essential Hypertension Groups
enm-2024-1985-Supplemental-Table-S1.pdf

Supplemental Table S2.

Comparison of Plasma Aldosterone Concentration and Aldosterone-to-Renin Ratio between Patients with and without Diabetes
enm-2024-1985-Supplemental-Table-S2.pdf

Supplemental Fig. S1.

Comparison of receiver operating characteristics curve for (A) liquid chromatography-tandem mass spectrometry (LC-MS/MS) plasma aldosterone concentration (PAC; dotted line) and radioimmunoassay (RIA) PAC (solid line), and (B) LC-MS/MS aldosterone- to-renin ratio (ARR; dotted line) and RIA ARR (solid line) for screening of primary aldosteronism.
enm-2024-1985-Supplemental-Fig-S1.pdf

Supplemental Fig. S2.

Receiver operating characteristics curve for liquid chromatography-tandem mass spectrometry (LC-MS/MS) plasma aldosterone concentration (PAC; orange line) and aldosterone-to-renin ratio (ARR; red line) including diabetes as covariate. DM, diabetes mellitus; AUC, area under the curve.
enm-2024-1985-Supplemental-Fig-S2.pdf

CONFLICTS OF INTEREST

No potential conflict of interest relevant to this article was reported.

AUTHOR CONTRIBUTIONS

Conception or design: S.Y.K., J.H.K. Acquisition, analysis, or interpretation of data: S.Y.K., K.J.K., S.Y.L. Drafting the work or revising: S.Y.K., J.H.K. Final approval of the manuscript: J.H.K.

Fig. 1.
Comparison of radioimmunoassay (RIA) and liquid chromatography-tandem mass spectrometry measurements of plasma aldosterone concentration (PAC) and plasma renin activity (PRA): Passing-Bablok regression analyses of (A) PAC and (B) PRA and Bland-Altman analyses of (C) PAC and (D) PRA. Essential hypertension (ET) is defined by liquid chromatography-tandem mass spectrometry (LC-MS/ MS) PAC as seated saline loading test ≤5.8 ng/dL; primary aldosteronism (PA) is defined by LC-MS/MS PAC as seated saline loading test >5.8 ng/dL (162 pmol/L). SD, standard deviation.
enm-2024-1985f1.jpg
enm-2024-1985f2.jpg
Table 1.
Performance of LC-MS/MS PAC and ARR Cutoff Values for Primary Aldosteronism Screening: Primary Aldosteronism vs. Essential Hypertension Confirmed by Seated Saline Loading Test
LC-MS/MS PAC, ng/dL Sensitivity, % Specificity, % LC-MS/MS ARR, ng/dL per ng/mL/hr Sensitivity, % Specificity, %
>4.0 100.0 10.7 >12.0 100.0 5.3
>6.7 90.4 36.0 >15.0 96.2 6.7
>8.0 86.5 46.7 >20.0 92.3 14.7
>10.3 73.1 57.3 >25.6 86.5 17.3
>12.2 61.5 65.3 >31.0 82.7 20.0
>14.7 57.7 76.0 >39.0 80.8 33.3
>16.0 51.9 82.7 >50.0 76.9 50.7
>18.0 50.0 89.3 >61.0 69.2 61.3
>20.0 38.5 92.0 >70.0 61.5 72.0
>22.3 38.5 94.7 >80.0 57.7 74.7
>24.2 36.5 97.3 >100.0 44.2 84.0
>27.0 30.8 100.0 >200.0 23.1 100.0

LC-MS/MS, liquid chromatography-tandem mass spectrometry; PAC, plasma aldosterone concentration; ARR, aldosterone-to-renin ratio.

  • 1. Monticone S, D’Ascenzo F, Moretti C, Williams TA, Veglio F, Gaita F, et al. Cardiovascular events and target organ damage in primary aldosteronism compared with essential hypertension: a systematic review and meta-analysis. Lancet Diabetes Endocrinol 2018;6:41–50.ArticlePubMed
  • 2. Wu X, Yu J, Tian H. Cardiovascular risk in primary aldosteronism: a systematic review and meta-analysis. Medicine (Baltimore) 2019;98:e15985.PubMedPMC
  • 3. Yoon M, Hong N, Ha J, Lee CJ, Ku CR, Rhee Y, et al. Prevalence and clinical characteristics of primary aldosteronism in a tertiary-care center in Korea. Hypertens Res 2022;45:1418–29.ArticlePubMedPDF
  • 4. Hua KF, Wu YH, Zhang ST. Clinical diagnostic value of liquid chromatography-tandem mass spectrometry method for primary aldosteronism in patients with hypertension: a systematic review and meta-analysis. Front Endocrinol (Lausanne) 2022;13:1032070.ArticlePubMedPMC
  • 5. Taylor PJ, Cooper DP, Gordon RD, Stowasser M. Measurement of aldosterone in human plasma by semiautomated HPLC-tandem mass spectrometry. Clin Chem 2009;55:1155–62.ArticlePubMedPDF
  • 6. Ha J, Park JH, Kim KJ, Kim JH, Jung KY, Lee J, et al. 2023 Korean Endocrine Society consensus guidelines for the diagnosis and management of primary aldosteronism. Endocrinol Metab (Seoul) 2023;38:597–618.ArticlePubMedPMCPDF
  • 7. Park SS, Kim JH. Recent updates on the management of adrenal incidentalomas. Endocrinol Metab (Seoul) 2023;38:373–80.ArticlePubMedPMCPDF
  • 8. Stowasser M, Ahmed AH, Cowley D, Wolley M, Guo Z, McWhinney BC, et al. Comparison of seated with recumbent saline suppression testing for the diagnosis of primary aldosteronism. J Clin Endocrinol Metab 2018;103:4113–24.ArticlePubMed
  • 9. Kwon SY, Park J, Park SH, Cho SH, Lee YB, Lee SY, et al. Aldosterone immunoassay-specific cutoff value for seated saline suppression test for diagnosing primary aldosteronism. Endocrinol Metab (Seoul) 2022;37:938–42.ArticlePubMedPMCPDF
  • 10. Zavatta G, Casadio E, Rinaldi E, Pagotto U, Pasquali R, Vicennati V. Aldosterone and type 2 diabetes mellitus. Horm Mol Biol Clin Investig 2016;26:53–9.ArticlePubMed
  • 11. Guo Z, Poglitsch M, McWhinney BC, Ungerer JP, Ahmed AH, Gordon RD, et al. Aldosterone LC-MS/MS assay-specific threshold values in screening and confirmatory testing for primary aldosteronism. J Clin Endocrinol Metab 2018;103:3965–73.ArticlePubMedPDF
  • 12. Thuzar M, Young K, Ahmed AH, Ward G, Wolley M, Guo Z, et al. Diagnosis of primary aldosteronism by seated saline suppression test-variability between immunoassay and HPLCMS/MS. J Clin Endocrinol Metab 2020;105:dgz150.ArticlePubMedPDF
  • 13. Burrello J, Monticone S, Buffolo F, Lucchiari M, Tetti M, Rabbia F, et al. Diagnostic accuracy of aldosterone and renin measurement by chemiluminescent immunoassay and radioimmunoassay in primary aldosteronism. J Hypertens 2016;34:920–7.ArticlePubMed
  • 14. Hung A, Ahmed S, Gupta A, Davis A, Kline GA, Leung AA, et al. Performance of the aldosterone to renin ratio as a screening test for primary aldosteronism. J Clin Endocrinol Metab 2021;106:2423–35.ArticlePubMedPDF

Figure & Data

References

    Citations

    Citations to this article as recorded by  

    Figure
    • 0
    • 1
    Comparative Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Radioimmunoassay in Determining Plasma Aldosterone Concentration and Plasma Renin Activity for Primary Aldosteronism Screening
    Image Image
    Fig. 1. Comparison of radioimmunoassay (RIA) and liquid chromatography-tandem mass spectrometry measurements of plasma aldosterone concentration (PAC) and plasma renin activity (PRA): Passing-Bablok regression analyses of (A) PAC and (B) PRA and Bland-Altman analyses of (C) PAC and (D) PRA. Essential hypertension (ET) is defined by liquid chromatography-tandem mass spectrometry (LC-MS/ MS) PAC as seated saline loading test ≤5.8 ng/dL; primary aldosteronism (PA) is defined by LC-MS/MS PAC as seated saline loading test >5.8 ng/dL (162 pmol/L). SD, standard deviation.
    Graphical abstract
    Comparative Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Radioimmunoassay in Determining Plasma Aldosterone Concentration and Plasma Renin Activity for Primary Aldosteronism Screening
    LC-MS/MS PAC, ng/dL Sensitivity, % Specificity, % LC-MS/MS ARR, ng/dL per ng/mL/hr Sensitivity, % Specificity, %
    >4.0 100.0 10.7 >12.0 100.0 5.3
    >6.7 90.4 36.0 >15.0 96.2 6.7
    >8.0 86.5 46.7 >20.0 92.3 14.7
    >10.3 73.1 57.3 >25.6 86.5 17.3
    >12.2 61.5 65.3 >31.0 82.7 20.0
    >14.7 57.7 76.0 >39.0 80.8 33.3
    >16.0 51.9 82.7 >50.0 76.9 50.7
    >18.0 50.0 89.3 >61.0 69.2 61.3
    >20.0 38.5 92.0 >70.0 61.5 72.0
    >22.3 38.5 94.7 >80.0 57.7 74.7
    >24.2 36.5 97.3 >100.0 44.2 84.0
    >27.0 30.8 100.0 >200.0 23.1 100.0
    Table 1. Performance of LC-MS/MS PAC and ARR Cutoff Values for Primary Aldosteronism Screening: Primary Aldosteronism vs. Essential Hypertension Confirmed by Seated Saline Loading Test

    LC-MS/MS, liquid chromatography-tandem mass spectrometry; PAC, plasma aldosterone concentration; ARR, aldosterone-to-renin ratio.


    Endocrinol Metab : Endocrinology and Metabolism
    TOP